Bellovac

Stor volumen drænage. Effektiv drænering, men med reduceret blodtab sammenlignet med høj vakuum drænage. (1)

Kirurgiske procedurer

  • Ortopædi
  • Gynækologi
  • Almen kirurgi

Komplette sæt

Bælg, drænagepose og kateter,  med eller uden trokar. 
Sættet er sterilt og klar til brug.

Max sugestyrke

115 mmHg - 15 kPa

Volumen

Bellows 220 ml
Bag 700 ml

Ref.nr.           Produkter 
68390  2x15  Bellovac® sæt FG 10 
68391  2x15  Bellovac® sæt FG 14 
68392  2x15  Bellovac® sæt FG 18 
68393  2x15  Bellovac® sæt FG 10 med trokar 
68394  2x15  Bellovac® sæt FG 14 med trokar 
68395  2x15  Bellovac® sæt FG 18 med trokar

1. Uncemented total knee replacement - the favourable influence of low over high pressure drainage. Morgan-Jones RL, Perko M MJ, Cross M, The Knee 7(2000) 149-150

Less blood loss with Bellovac

Uncemented total knee replacement - the favourable influence of low over high pressure drainage.
Morgan-Jones RL, Perko MM, Cross MJ.
Knee 2000 Jul 1;7(3):149-150

122 uncemented total knee replacements were randomised to either have high pressure drainage or low pressure drainage (Bellovac®)
The total blood loss was significantly lower in the low vacuum group, compared to the patients that had a high vacuum drain (mean blood loss 1364 ml vs 1695 ml, p<0,0062).
According to the authors, “the blood loss following knee replacement operations is substantial and can also be affected by the vacuum pressure in suction drains”.“High suction pressure drains are not necessary, and may be detrimental when used following uncemented total knee eplacement”

Bellovac wound drainage Wellspect HealthCare

Sortiment

Ref No               Produkt
68390    2x15    Bellovac Set FG 10
68391    2x15    Bellovac Set FG 14
68392    2x15    Bellovac Set FG 18
68393    2x15    Bellovac Set FG 10 med trokar
68394    2x15    Bellovac Set FG 14 med trokar
68395    2x15    Bellovac Set FG 18 med trokar

Less blood loss with Bellovac

Uncemented total knee replacement - the favourable influence of low over high pressure drainage.

Morgan-Jones RL, Perko MM, Cross MJ.
Knee 2000 Jul 1;7(3):149-150

  • 122 uncemented total knee replacements were randomised to either have high pressure drainage or low pressure drainage (Bellovac)
  • The total blood loss was significantly lower in the low vacuum group, compared to the patients that had a high vacuum drain (mean blood loss 1364 ml vs 1695 ml, p<0,00062).
  • According to the authors, “the blood loss following knee replacement operations is substantial and can also be affected by the vacuum pressure in suction drains”.“High suction pressure drains are not necessary, and may be detrimental when used following uncemented total knee replacement” 
Link to PubMed